Air conditioning guide: which split air conditioner is right for you?

Guide · Air conditioners

A split air conditioner cools in summer and heats in the transitional season – efficiently and quietly, because the compressor sits outside. With us you always buy air conditioners as a complete set of indoor and outdoor unit.

Here you can read which output suits your room, what SEER and SCOP mean, who may install the system and which set from our shop suits you.

All air conditionersGo straight to the model comparison ↓

The key points in brief

Always as a setIndoor and outdoor units are matched to each other and are sold together.
Output according to cooling loadRoom size is only the beginning. Insulation, window areas and sun determine how much output is needed.
Cooling and heatingAll sets in our shop can also heat. As air-to-air heat pumps, they complement the heating system well.
Installation by a specialist companyPermanently installed split units are connected by a certified refrigeration specialist. The PortaSplit is the mobile exception.

How a split air conditioner works

A split air conditioner consists of two units: the indoor unit hangs on the wall and distributes the air in the room, the outdoor unit contains the compressor and fan. Both are connected via refrigerant lines, a control cable and the condensate drain. When cooling, the refrigerant absorbs heat from the room air in the indoor unit and releases it outside. At the same time, the air is dehumidified.

Because the noisy compressor sits outside, the indoor unit is very quiet – for the Solstice sets, according to the manufacturer, from 19 to 21.5 dB(A) at the quietest level. Thanks to inverter technology, the system regulates its output continuously and usually runs in economical partial-load operation.

MonosplitAll permanently installed sets in our shop are monosplit systems: one outdoor unit supplies one indoor unit. For several rooms, you need either several sets or a multisplit system.

Which output for which room?

Cooling capacity is given in kilowatts. The manufacturers provide guide values for room size for the sets – always depending on the cooling load:

Cooling capacity Guide value according to manufacturer Sets in our shop
2.6 kW up to approx. 30 m² (Solstice 09) Solstice 09 black · Solstice 09 white · Breezeless E 09
3.5 kW up to approx. 40 m² (Solstice 12), PortaSplit up to approx. 42 m² Solstice 12 black · Solstice 12 white · Xtreme Save Blue 12 · Breezeless E 12 · PortaSplit
5.0 kW larger rooms, open-plan living areas Solstice 18 white
7.0 kW up to approx. 70 m² (Xtreme Save Pro 24) Xtreme Save Pro 24

Rooms under the roof, with large south- or west-facing windows and with many people or devices need more output. An oversized unit cools quickly, but switches off often and dehumidifies less well. If in doubt, the specialist company calculates the cooling load.

SEER and SCOP: how to read efficiency

SEER – coolingThe seasonal energy efficiency ratio for cooling. A SEER of 8.5 means: over the cooling season, one kilowatt hour of electricity produces an average of 8.5 kWh of cooling. From 8.5, the class is A+++.
SCOP – heatingThe seasonal coefficient of performance for heating, usually for the "average" climate zone. A SCOP of 4.6 corresponds to A++, from 5.1 the class is A+++.
Partial load countsBoth values take into account operation at different temperatures and loads – more meaningful than the rated power consumption.

Heating with the air conditioner

A split air conditioner with a heating function is an air-to-air heat pump. It draws heat from the outside air and releases it directly into the room air. This is fast and efficient – ideal for the transitional season, for individual rooms such as an office or attic and as a supplement to the existing heating system.

According to the manufacturer, the Solstice sets heat down to −25 °C outside temperature, the Xtreme Save Pro 24 down to −20 °C, the Xtreme Save Blue 12 down to −15 °C and the PortaSplit down to −10 °C. In frost, the available output decreases. An air conditioner does not produce hot water. For heating and hot water in the whole house, an air-to-water heat pump is the right solution; more on this in the heat pump guide.

Refrigerant: R32 or R290

Most sets in our shop work with R32, a widely used fluorinated refrigerant. The Xtreme Save Blue 12 uses the natural refrigerant R290 (propane) with a very low global warming potential and, according to the manufacturer, has been awarded the Blue Angel (Blauer Engel) eco-label. R290 is flammable, R32 is considered mildly flammable. For both, requirements for installation and room size from the installation instructions apply.

Installation by a refrigeration specialist

With permanently installed split systems, the specialist company connects the indoor and outdoor units via the refrigerant lines. It checks for leaks, evacuates the lines and commissions the system. This work on the refrigerant circuit may only be carried out by certified refrigeration specialists. So plan the appointment when you make your purchase.

Line lengthSolstice 09 and 12 as well as Xtreme Save Blue 12: up to 25 m line and 10 m height difference. Solstice 18: up to 30 m and 20 m.
Line setRefrigerant lines and mounting accessories are not automatically included in the set. A line set is optionally available for some sets.
Condensate & powerThe condensate needs a drain with a gradient or a pump. The sets run on 230 V; the fuse protection is specified in the datasheet.
The mobile exception: PortaSplitWith the Midea PortaSplit the indoor and outdoor units are coupled via a permanently connected, flat refrigerant hose. The outdoor unit goes into the supplied window bracket or onto a balcony or terrace, the plug into a normal socket. No drilling or specialist company is required for setup – but work on the refrigerant circuit still requires one. Ideal for rented flats.

Running the air conditioner on PV surplus

Cooling demand and solar power match perfectly in time: it is hottest when the PV system delivers the most. According to the manufacturer, a 3.5 kW system such as the Solstice 12 draws around 1.1 kW in rated operation, significantly less in partial-load operation. A PV system can cover a large part of this directly on sunny days.

Schedules and temperatures can be controlled via the Midea SmartHome app, including energy reports for the Solstice sets. With a battery, the air conditioner also runs on your own electricity in the evening.

VATAir conditioners are not PV components and are not covered by the zero tax rate. They are sold with regular VAT (19% in Germany); there is no 0% option. More on this: 0% VAT on PV – what applies?

Air conditioners compared

Set Cooling / heating (rated) SEER / SCOP Refrigerant Special feature
Solstice 09 black 2.6 / 2.9 kW 8,8 / 4,6 R32 black indoor unit, 180° air outlet
Solstice 09 white 2.6 / 2.9 kW 8,8 / 4,6 R32 white indoor unit, 180° air outlet
Solstice 12 black 3.5 / 3.8 kW 8,5 / 4,6 R32 AI EcoMaster, app with energy reports
Solstice 12 white 3.5 / 3.8 kW 8,5 / 4,6 R32 white indoor unit
Solstice 18 white 5.0 / 5.4 kW 8,5 / 5,7 R32 for large rooms, up to 30 m line
Xtreme Save Blue 12 3.52 / 3.81 kW 8,5 / 4,6 R290 natural refrigerant, Blue Angel
Xtreme Save Pro 24 7.0 / 7.3 kW 6,4 / 4,0 R32 for rooms up to approx. 70 m²
Breezeless E 09 Size 09 see product page R32 Breezeless Mode for draught-free air
Breezeless E 12 Size 12 see product page R32 Breezeless Mode for draught-free air
PortaSplit (mobile) 3.5 / 3.5 kW 6,1 / 4,0 R32 no drilling, 230 V socket

All sets consist of an indoor and an outdoor unit. With the Breezeless E sets, the indoor unit is combined with a Solstice outdoor unit. For this pairing, the manufacturer does not specify separate system values for output, SEER and SCOP – sizing is carried out with the specialist company using the device data on the product page.

Decision guide: you want … → choose …

Quietly cool a bedroom or children's room up to approx. 30 m².→ Solstice 09 white→ Solstice 09 black
A living room or office up to approx. 40 m², also for heating in the transitional season.→ Solstice 12 white→ Solstice 12 black
A unit with natural refrigerant.→ Xtreme Save Blue 12
A large open-plan living area.→ Solstice 18→ Xtreme Save Pro 24
As little draught in the room as possible.→ Breezeless E 09→ Breezeless E 12
Cooling in a rented flat without drilling.→ PortaSplit

The matching products

Midea split air conditioner complete set Solstice 12 3.5 kW Air conditioner · 3.5 kW · R32 Solstice 12 Split complete set, SEER 8.5 / SCOP 4.6, guide value up to approx. 40 m². To the product → Midea split air conditioner complete set Solstice 09 2.6 kW white Air conditioner · 2.6 kW · white Solstice 09 white SEER 8.8 / SCOP 4.6, heats down to −25 °C outside temperature. To the product → Midea split air conditioner complete set Xtreme Save Blue 12 3.5 kW Air conditioner · 3.5 kW · R290 Xtreme Save Blue 12 Natural refrigerant R290, SEER 8.5 / SCOP 4.6. To the product → Midea split air conditioner complete set Solstice 18 5.0 kW white Air conditioner · 5.0 kW · white Solstice 18 white For large rooms, SEER 8.5 / SCOP 5.7. To the product → Midea split air conditioner complete set Xtreme Save Pro 24 7.0 kW Air conditioner · 7.0 kW Xtreme Save Pro 24 The highest output in our shop, guide value up to approx. 70 m². To the product → Midea mobile split air conditioner PortaSplit 3.5 kW Mobile split air conditioner · 3.5 kW PortaSplit Split technology without drilling – outdoor unit in the window or on the balcony. To the product → Midea split air conditioner complete set Breezeless E 12 Air conditioner · Size 12 Breezeless E 12 Wall unit with Breezeless Mode for almost draught-free air. To the product →

You will find all sets under Air conditioners. Heating and hot water for the whole house? Then read our heat pump guide.

3 mistakes you should avoid

1. Buying by square metres onlyAttics and large glass areas need more output than the room size suggests.
2. Looking for a specialist company too lateWithout a refrigeration specialist, a permanently installed split set cannot be commissioned. Plan the appointment early.
3. Placing the outdoor unit incorrectlyFree air supply, distance to the neighbours and a clean condensate drain determine efficiency and quietness.

Frequently asked questions

Do I get the indoor and outdoor units together?

Yes. We always sell air conditioners as a complete set of matched indoor and outdoor units.

May I install a split air conditioner myself?

You can prepare the wall and outdoor unit, but the work on the refrigerant circuit – connecting lines, checking for leaks, evacuating and commissioning – may only be carried out by a certified refrigeration specialist. The PortaSplit is sealed at the factory and is set up without a specialist company.

Can I heat with the air conditioner?

Yes, all sets in our shop can heat. As air-to-air heat pumps, they work very efficiently in the transitional season. They do not prepare hot water.

How much electricity does an air conditioner use?

That depends on the unit, room and weather. According to the manufacturer, the Solstice 12 draws around 1.1 kW in rated cooling operation, significantly less in partial-load operation. A high SEER value reduces consumption over the season.

How loud is the indoor unit?

At the quietest level, Midea specifies 19 to 21.5 dB(A) for the Solstice sets. According to the manufacturer, the PortaSplit reaches 39 dB(A) in silent mode.

Which is better: R32 or R290?

Both are efficient. R290 is a natural refrigerant with a very low global warming potential, R32 is widely used. In our shop, the Xtreme Save Blue 12 works with R290.

Are there air conditioners with 0% VAT?

No. Air conditioners do not fall under the zero tax rate for PV systems and are sold with regular VAT (19% in Germany).

Do I need several sets for several rooms?

With the monosplit sets in our shop, one outdoor unit supplies one indoor unit. So for several rooms you need several sets.

Your air conditioner – as a complete set

You can get split sets in various outputs and the mobile PortaSplit from us. Send us the room size, location and your requirements – we will help you choose.

Note: This guide does not replace planning by a refrigeration specialist. Check cooling load, installation location, line routing and condensate drainage before purchase using the manufacturer's current documentation.

All information without guarantee. Subject to technical changes and errors. The current manufacturer documentation is authoritative.

Back to blog